Gas Mixers

8300, 8350, 8400, 8450, 8600 Series

Features

  • Designed for the mixing of Helium & Nitrogen and Helium & Argon
  • Continuous gas analysis of the gas mixture
  • Infinite flow rate turndown
  • Gas mixture may be easily adjusted to optimum setpoint
  • Built-in alarms to alert personnel for improper conditions. Remote alarm control available
  • Ideal for furnace and welding applications
  • For multiple furnace applications, single station mixing improves safety and management control of the mixture
  • The furnace atmosphere models meet the applicable sections of NFPA86C
  • Available in standard capacities of 0-2000, 0-5000 and 0-10000 SCFH
  • Mixing accuracy: +-3% (10C-32C), +-5% (-12C-40C)
  • Inlet pressure: 0.7-0.9MPa, Outlet pressure: 0.07-0.34MPa
  • Voltage: 220 VAC (110 VAC available upon request)
  • Dimensions: 8300, 8350: 1040mm x 790mm x 1400mm, 8400, 8450: 1300mm x 970mm x 1600mm, 8600: 1900mm x 1070mm x 1830mm
  • Weight: 8300 & 8350: 128kg: 8400&8450: 181kg: 8600: 297kg
  • Quantity:

    Related Products